Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 6396, 2023 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-37076541

RESUMO

Optical coherence tomography angiography (OCTA) provides three-dimensional structural and semiquantitative imaging of microvasculature in vivo. We developed an OCTA imaging protocol for a murine kidney ischemia-reperfusion injury (IRI) model to investigate the correlation between renal microvascular changes and ischemic damage. Mice were divided into mild and moderate IRI groups according to the duration of ischemia (10 and 35 mins, respectively). Each animal was imaged at baseline; during ischemia; and at 1, 15, 30, 45, and 60 mins after ischemia. Amplitude decorrelation OCTA images were constructed with 1.5-, 3.0-, and 5.8-ms interscan times, to calculate the semiquantitative flow index in the superficial (50-70 µm) and the deep (220-340 µm) capillaries of the renal cortex. The mild IRI group showed no significant flow index change in both the superfial and the deep layers. The moderate IRI group showed a significantly decreased flow index from 15 and 45 mins in the superficial and deep layers, respectively. Seven weeks after IRI induction, the moderate IRI group showed lower kidney function and higher collagen deposition than the mild IRI group. OCTA imaging of the murine IRI model revealed changes in superficial blood flow after ischemic injury. A more pronounced decrease in superficial blood flow than in deep blood flow was associated with sustained dysfunction after IRI. Further investigation on post-IRI renal microvascular response using OCTA may improve our understanding of the relationship between the degree of ischemic insult and kidney function.


Assuntos
Traumatismo por Reperfusão , Tomografia de Coerência Óptica , Camundongos , Animais , Rim/diagnóstico por imagem , Rim/irrigação sanguínea , Traumatismo por Reperfusão/diagnóstico por imagem , Traumatismo por Reperfusão/complicações , Isquemia/diagnóstico por imagem , Isquemia/complicações , Microvasos/diagnóstico por imagem , Angiografia
2.
Opt Express ; 30(26): 46956-46971, 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36558634

RESUMO

We present an innovative ellipsometry technique called self-interferometric pupil ellipsometry (SIPE), which integrates self-interference and pupil microscopy techniques to provide the high metrology sensitivity required for metrology applications of advanced semiconductor devices. Due to its unique configuration, rich angle-resolved ellipsometric information from a single-shot hologram can be extracted, where the full spectral information corresponding to incident angles from 0° to 70° with azimuthal angles from 0° to 360° is obtained, simultaneously. The performance and capability of the SIPE system were fully validated for various samples including thin-film layers, complicated 3D structures, and on-cell overlay samples on the actual semiconductor wafers. The results show that the proposed SIPE system can achieve metrology sensitivity up to 0.123 nm. In addition, it provides small spot metrology capability by minimizing the illumination spot diameter up to 1 µm, while the typical spot diameter of the industry standard ellipsometry is around 30 µm. As a result of collecting a huge amount of angular spectral data, undesirable multiple parameter correlation can be significantly reduced, making SIPE ideally suited for solving several critical metrology challenges we are currently facing.

3.
Neuroimage ; 263: 119597, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36044945

RESUMO

For confidence of memory, a neural basis such as traces of stored memories should be required. However, because false memories have never been stored, the neural basis for false memory confidence remains unclear. Here we monitored the brain activity in participants while they viewed learned or novel objects, subsequently decided whether each presented object was learned and assessed their confidence levels. We found that when novel objects are presented, false memory confidence significantly depends on the shared representations with learned objects in the prefrontal cortex. However, such a tendency was not found in posterior regions including the visual cortex, which may be involved in the processing of perceptual gist. Furthermore, the confidence-dependent shared representations were not observed when participants correctly answered novel objects as non-learned objects. These results demonstrate that false memory confidence is critically based on the reinstatement of high-level semantic gist of stored memories in the prefrontal cortex.


Assuntos
Memória , Córtex Visual , Humanos , Mapeamento Encefálico , Imageamento por Ressonância Magnética , Córtex Pré-Frontal
4.
J Biomed Opt ; 25(12)2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33331149

RESUMO

SIGNIFICANCE: Evaluation of vessel patency and blood flow direction is important in various medical situations, including diagnosis and monitoring of ischemic diseases, and image-guided vascular surgeries. While optical coherence tomography angiography (OCTA) is the most widely used functional extension of optical coherence tomography that visualizes three-dimensional vasculature, inability to provide information of blood flow direction is one of its limitations. AIM: We demonstrate two-dimensional (2D) transverse blood flow direction imaging in en face OCTA. APPROACH: A series of triangular beam scans for the fast axis was implemented in the horizontal direction for the first volume scan and in the vertical direction for the following volume scan, and the inter A-line OCTA was performed for the blood flow direction imaging while the stepwise pattern was used for each slow axis scan. The decorrelation differences between the forward and the backward inter A-line OCTA were calculated for the horizontal and the vertical fast axis scans, and the ratio of the horizontal and the vertical decorrelation differences was utilized to show the 2D transverse flow direction information. RESULTS: OCTA flow direction imaging was verified using flow phantoms with various flow orientations and speeds, and we identified the flow speed range relative to the scan speed for reliable flow direction measurement. We demonstrated the visualization of 2D transverse blood flow orientations in mouse brain vascular networks in vivo. CONCLUSIONS: The proposed OCTA imaging technique that provides information of 2D transverse flow direction can be utilized in various clinical applications and preclinical studies.


Assuntos
Angiografia , Tomografia de Coerência Óptica , Animais , Angiofluoresceinografia , Camundongos , Imagens de Fantasmas
5.
Sci Rep ; 10(1): 9328, 2020 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-32518256

RESUMO

In optical coherence tomography (OCT), high-speed systems based at 1300 nm are among the most broadly used. Here, we present 9.4 MHz A-line rate OCT system at 1300 nm. A wavelength-swept laser based on stretched-pulse active mode locking (SPML) provides a continuous and linear-in-wavenumber sweep from 1240 nm to 1340 nm, and the OCT system using this light source provides a sensitivity of 98 dB and a single-sided 6-dB roll-off depth of 2.5 mm. We present new capabilities of the 9.4 MHz SPML-OCT system in three microscopy applications. First, we demonstrate high quality OCTA imaging at a rate of 1.3 volumes/s. Second, by utilizing its inherent phase stable characteristics, we present wide dynamic range en face Doppler OCT imaging with multiple time intervals ranging from 0.25 ms to 2.0 ms at a rate of 0.53 volumes/s. Third, we demonstrate video-rate 4D microscopic imaging of a beating Xenopus embryo heart at a rate of 30 volumes/s. This high-speed and high-performance OCT system centered at 1300 nm suggests that it can be one of the most promising high-speed OCT platforms enabling a wide range of new scientific research, industrial, and clinical applications at speeds of 10 MHz.


Assuntos
Lasers , Tomografia de Coerência Óptica/métodos , Animais , Coração/diagnóstico por imagem , Imageamento Tridimensional , Controle de Qualidade , Xenopus/embriologia
7.
Korean J Anesthesiol ; 60(6): 437-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21738848

RESUMO

We experienced difficulty in ventilating the lungs of a patient after tracheal intubation. After intubation, an insufficient amount of tidal volume (V(T)) was delivered to the patient and the fiberoptic bronchoscopic examination identified partial abutment of the endotracheal tube (ETT) orifice against the tracheal wall. After various attempts to correctly place the ETT, a double-lumen endotracheal tube was placed to achieve a sufficient V(T). It is important to notice that even an appropriately placed ETT may get obstructed due to the left sided bevel at its tip.

8.
Korean J Anesthesiol ; 61(6): 515-8, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22220231

RESUMO

A pulmonary embolism and cerebral infarction are the second and third most common acute cardiovascular diseases after a myocardial infarction. Early diagnosis and appropriate management are important clinical challenges. In this case, a fatal pulmonary embolism and extensive cerebral infarction caused cardiac arrest during spinal anesthesia for total hip replacement surgery. Transesophageal echocardiography indicated a pulmonary embolism and brain CT showed large area of acute infarction at right middle cerebral artery territory. Pulmonary CT angiogram revealed massive pulmonary embolism findings. This paper reviews this case and suggests other preventive modalities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...